Showing all 9 results
Flow Meter TCS 700-15
Specification TCS 700-15
- Flow: Capable of up to 60 GPM (227 LPM); Bi-directional Flow
- Flange Connections: 1 1/2” NPT Flange; 1” & 2” Options
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-20
Specification Flow Meter TCS 700-20
- Flow: Capable of up to 100 GPM (380 LPM); Bi-directional Flow
- Flange Connections: 2” NPT Flange; 1 1/2” Option
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-25
Specification Flow Meter TCS 700-25
- Flow: Capable of up to 150 GPM (567 LPM); Bi-directional Flow
- Flange Connections: 2” NPT Flange
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-30
Specification TCS 700-30
- Flow: Capable of up to 200 GPM (760 LPM); Bi-directional Flow
- Flange Connections: 3” NPT Flange; 2” Option
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-35
Specification Flow Meter TCS 700-35
- Flow: Capable of up to 300 GPM (1,135 LPM); Bi-directional Flow
- Flange Connections: 3” NPT Flange
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-40
Specification TCS 700-40
- Flow: Capable of up to 500 GPM (1,893 LPM); Bi-directional Flow
- Flange Connections: 4” NPT Flange; 3” Option
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-45
Specification TCS 700-45
- Flow: Capable of up to 600 GPM (2,271 LPM); Bi-directional Flow
- Flange Connections: 4” NPT Flange
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-60
Specification TCS 700-60
- Flow: Capable of up to 800 GPM (3,040 LPM); Bi-directional Flow
- Flange Connections: 6” ANSI Flange
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)
Flow Meter TCS 700-65
Specification TCS 700-65
- Flow: Capable of up to 1,000 GPM (3,800 LPM); Bi-directional Flow
- Flange Connections: 6” ANSI Flange
- Linear Accuracy: Capable of ± 0.15% of over the full flow range
- Repeatability: Capable of 0.02% (constant operation conditions with 700SP meters & mechanical registration, using 1 CPS test fluid)
- Viscosity: Will accurately measure liquids up to 1,500,000 SSU (325,000 CPS)
- Working Pressure: 150 PSI (10.5 BAR)
- Working Temperature: – 40 to 160°F (- 40 to 71°C)